array(17) {
["IdNr"]=>
string(2) "78"
["online-11"]=>
string(1) "1"
["redAnzeige-11"]=>
string(1) "1"
["anwId"]=>
string(3) "|4|"
["prodId"]=>
string(7) "|48|49|"
["verlegId"]=>
string(7) "|1|2|5|"
["besondId"]=>
string(2) "||"
["ankerUrl"]=>
string(48) "emds-protective-pipe-for-a-new-it-infrastructure"
["titel"]=>
string(48) "EMDS Protective pipe for a new IT infrastructure"
["detailtitel"]=>
string(81) "Media connection Campus Charite Mitte
Berlin - Hessische Straße
Cable conduits"
["teaser"]=>
string(43) "Digitisation for the medicine of the future"
["detail"]=>
string(405) ""Digitalisation is a central building block for shaping the coming decades of health care, research and teaching. A modern and well-equipped IT infrastructure is the prerequisite for implementing almost all of our strategic goals. These include the development of a digitalised university medicine, the acceleration of translation and the profiling of regional and supra-regional care networks.""
["RohrTyp"]=>
string(328) "EMDS conduit pipe Basic performance class PE-HD+
DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 12 m
+ Coils of 100 m and 200 m
EMDS conduit pipe Basic performance class PE-HD+
DN/OD 140 x 12.7 mm SDR 11, Coils of 235 m
EMDS conduit pipe Basic performance class PE100
DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 6 m"
["Verlegung"]=>
string(0) ""
["Kontakt"]=>
string(145) "Anwendungstechnik Gerodur
Andreas-Schubert-Straße 6
D-01844 Neustadt in Sachsen
Telefon: +49 3596 58330
E-Mail: anwendungstechnik@gerodur.de"
["dnl"]=>
string(0) ""
["dnl_titel"]=>
string(0) ""
}
EMDS Protective pipe for a new IT infrastructure
Media connection Campus Charite Mitte
Berlin - Hessische Straße
Cable conduits
Berlin - Hessische Straße
Cable conduits
"Digitalisation is a central building block for shaping the coming decades of health care, research and teaching. A modern and well-equipped IT infrastructure is the prerequisite for implementing almost all of our strategic goals. These include the development of a digitalised university medicine, the acceleration of translation and the profiling of regional and supra-regional care networks."
TECHNICAL SPECIFICATIONS
Type of pipe
EMDS conduit pipe Basic performance class PE-HD+
DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 12 m
+ Coils of 100 m and 200 m
EMDS conduit pipe Basic performance class PE-HD+
DN/OD 140 x 12.7 mm SDR 11, Coils of 235 m
EMDS conduit pipe Basic performance class PE100
DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 6 m
DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 12 m
+ Coils of 100 m and 200 m
EMDS conduit pipe Basic performance class PE-HD+
DN/OD 140 x 12.7 mm SDR 11, Coils of 235 m
EMDS conduit pipe Basic performance class PE100
DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 6 m
Installation
Sand bedding
Without sand bedding
Horizontal Directional Drillling (HDD)
Without sand bedding
Horizontal Directional Drillling (HDD)
Contact
Anwendungstechnik Gerodur
Andreas-Schubert-Straße 6
D-01844 Neustadt in Sachsen
Telefon: +49 3596 58330
E-Mail: anwendungstechnik@gerodur.de
Andreas-Schubert-Straße 6
D-01844 Neustadt in Sachsen
Telefon: +49 3596 58330
E-Mail: anwendungstechnik@gerodur.de