array(17) { ["IdNr"]=> string(2) "78" ["online-11"]=> string(1) "1" ["redAnzeige-11"]=> string(1) "1" ["anwId"]=> string(3) "|4|" ["prodId"]=> string(7) "|48|49|" ["verlegId"]=> string(7) "|1|2|5|" ["besondId"]=> string(2) "||" ["ankerUrl"]=> string(48) "emds-protective-pipe-for-a-new-it-infrastructure" ["titel"]=> string(48) "EMDS Protective pipe for a new IT infrastructure" ["detailtitel"]=> string(81) "Media connection Campus Charite Mitte Berlin - Hessische Straße Cable conduits" ["teaser"]=> string(43) "Digitisation for the medicine of the future" ["detail"]=> string(405) ""Digitalisation is a central building block for shaping the coming decades of health care, research and teaching. A modern and well-equipped IT infrastructure is the prerequisite for implementing almost all of our strategic goals. These include the development of a digitalised university medicine, the acceleration of translation and the profiling of regional and supra-regional care networks."" ["RohrTyp"]=> string(328) "EMDS conduit pipe Basic performance class PE-HD+ DN/­OD 180 x 16.4 mm SDR 11, Straight lenghts of 12 m + Coils of 100 m and 200 m EMDS conduit pipe Basic performance class PE-HD+ DN/OD 140 x 12.7 mm SDR 11, Coils of 235 m EMDS conduit pipe Basic performance class PE100 DN/OD 180 x 16.4 mm SDR 11, Straight lenghts of 6 m" ["Verlegung"]=> string(0) "" ["Kontakt"]=> string(145) "Anwendungstechnik Gerodur Andreas-Schubert-Straße 6 D-01844 Neustadt in Sachsen Telefon: +49 3596 58330 E-Mail: anwendungstechnik@gerodur.de" ["dnl"]=> string(0) "" ["dnl_titel"]=> string(0) "" }

EMDS Protective pipe for a new IT infrastructure

Media connection Campus Charite Mitte
Berlin - Hessische Straße
Cable conduits
Digitisation for the medicine of the future
"Digitalisation is a central building block for shaping the coming decades of health care, research and teaching. A modern and well-equipped IT infrastructure is the prerequisite for implementing almost all of our strategic goals. These include the development of a digitalised university medicine, the acceleration of translation and the profiling of regional and supra-regional care networks."

TECHNICAL SPECIFICATIONS

Type of pipe
 
EMDS conduit pipe Basic performance class PE-HD+
DN/­­OD 180 x 16.4 mm SDR 11, Straight lenghts of 12 m
+ Coils of 100 m and 200 m
EMDS conduit pipe Basic performance class PE-HD+
DN/­OD 140 x 12.7 mm SDR 11, Coils of 235 m
EMDS conduit pipe Basic performance class PE100
DN/­OD 180 x 16.4 mm SDR 11, Straight lenghts of 6 m
Installation
 
Sand bedding
Without sand bedding
Horizontal Directional Drillling (HDD)
Contact
 
Anwendungstechnik Gerodur
Andreas-Schubert-Straße 6
D-01844 Neustadt in Sachsen
Telefon: +49 3596 58330
E-Mail: anwendungstechnik@gerodur.de
  • EMDS PE-HD+ PE100 - Kabelschutzrohr neue IT-Infrastruktur Campus Charite Mitte Rohrbündel
  • EMDS - Kabelschutzrohr Campus Charite Mitte Bündeleinzug Spülbohren (HDD) Bündeleinzug Rohre
  • EMDS - Kabelschutzrohr Campus Charite Mitte Spülbohren (HDD) Rohreinzug austretendes Rohrende
  • EMDS - Kabelschutzrohr Campus Charite Mitte Bündeleinzug Parallelverlegung Ringbunde
  • EMDS - Kabelschutzrohr Campus Charite Mitte Bündeleinzug Parallelverlegung
  • EMDS PE-HD+ PE100 - Kabelschutzrohr Campus Charite Mitte Spülbohren (HDD) Bohrgerät
EMDS PE-HD+ PE100 - Kabelschutzrohr neue IT-Infrastruktur Campus Charite Mitte RohrbündelEMDS - Kabelschutzrohr Campus Charite Mitte Bündeleinzug Spülbohren (HDD) Bündeleinzug RohreEMDS - Kabelschutzrohr Campus Charite Mitte Spülbohren (HDD) Rohreinzug austretendes RohrendeEMDS - Kabelschutzrohr Campus Charite Mitte Bündeleinzug Parallelverlegung RingbundeEMDS - Kabelschutzrohr Campus Charite Mitte Bündeleinzug Parallelverlegung EMDS PE-HD+ PE100 - Kabelschutzrohr Campus Charite Mitte Spülbohren (HDD) Bohrgerät